Carpet Manufacturer | Carpet Name | Carpet Grade | Underlay type | CRF RATING (kW/m^2) | Smoke Rate (%) | Comments |
---|---|---|---|---|---|---|
Allied Floor Coverings | Weavers Choice | 700GSM | Stepsmart | 1.2 | 501 | OK for buildings fitted with sprinkler system. Class 2,3,5,6,7,8 or 9b except fire isolated exits |
Beaulieu | Resistain | 24 oz SDN | Stepsmart | 2.8 | 300 | OK for buildings not fitted with sprinkler system. Class 2,3,5,6,7,8 or 9b |
Beaulieu | 26 oz SDN | 26 oz SDN | Stepsmart | 2.2 | 327 | OK for buildings not fitted with sprinkler system. Class 2,3,5,6,7,8 or 9b |
Beaulieu | Resistain | 28 oz SDN | Stepsmart | 3.8 | 286 | OK for buildings not fitted with sprinkler system. Class 2,3,5,6,7,8 or 9b |
Beaulieu | Capital Hill | 22oz/yd^2 SDN | Stepsmart | 2.2 | 273 | OK for buildings not fitted with sprinkler system. Class 2,3,5,6,7,8 or 9b |
Beaulieu | Critics Choice | 26oz/yd^2 SDN | Stepsmart | 1.5 | 292 | OK for buildings fitted with sprinkler system. Class 2,3,5,6,7,8 or 9b except fire isolated exits |
Beaulieu | Critics Choice | 26oz/yd^2 SDN | Steplight | 2.4 | 218 | OK for buildings not fitted with sprinkler system. Class 2,3,5,6,7,8 or 9b |
Beaulieu | Directors Office | 26oz/yd^2 SDN | Stepsmart | 1.9 | 318 | OK for buildings fitted with sprinkler system. Class 2,3,5,6,7,8 or 9b except fire isolated exits |
Beaulieu | El Camino | 40 oz/yd^2 Resistain SDN | Step 160 | 2.3 | 378 | OK for buildings not fitted with sprinkler system. Class 2,3,5,6,7,8 or 9b |
Beaulieu | High Tech | 680g/m^2 SDN | Stepsmart | 1.8 | 302 | OK for buildings fitted with sprinkler system. Class 2,3,5,6,7,8 or 9b except fire isolated exits |
Beaulieu | Lahrs Lane | 22oz/yd^2 SDN | Stepsmart | 4.5 | 144 | OK for buildings not fitted with sprinkler system. Class 2,3,5,6,7,8 or 9b |
Beaulieu | Liberation | 24oz/yd^2 SDN | Stepsmart | 1.9 | 254 | OK for buildings fitted with sprinkler system. Class 2,3,5,6,7,8 or 9b except fire isolated exits |
Beaulieu | Liberation | 24 oz/yd^2 SDN | Steplight | 3.7 | 179 | OK for buildings not fitted with sprinkler system. Class 2,3,5,6,7,8 or 9b |
Beaulieu | Mantra | 34oz/yd^2 SDN | Stepsmart | 2.2 | 369 | OK for buildings not fitted with sprinkler system. Class 2,3,5,6,7,8 or 9b |
Beaulieu | Medallion | 26oz/yd^2 Resistain SDN | Stepsmart | 2.2 | 327 | OK for buildings not fitted with sprinkler system. Class 2,3,5,6,7,8 or 9b |
Beaulieu | Medallion | 26oz/yd^2 Resistain SDN | Step 160 | 1.5 | 233 | OK for buildings fitted with sprinkler system. Class 2,3,5,6,7,8 or 9b except fire isolated exits |
Beaulieu | Racing Silks | 40 oz/yd^2, 100% SDN | Steplight | 2.3 | 169 | OK for buildings not fitted with sprinkler system. Class 2,3,5,6,7,8 or 9b |
Beaulieu | Royal Plush | 24 oz/yd^2 NYLON | Stepsmart | 2.7 | 280 | OK for buildings not fitted with sprinkler system. Class 2,3,5,6,7,8 or 9b |
Beaulieu | Royal Plush 24 | 24oz/yd^2 SDN | Stepsmart | 2.7 | 280 | OK for buildings not fitted with sprinkler system. Class 2,3,5,6,7,8 or 9b |
Beaulieu | Royal Plush 30 | 30oz/yd^2 SDN | Stepsmart | 2.4 | 263 | OK for buildings not fitted with sprinkler system. Class 2,3,5,6,7,8 or 9b |
Beaulieu | Tornado | 22oz/yd^2 SDN | Stepsmart | 1.3 | 350 | OK for buildings fitted with sprinkler system. Class 2,3,5,6,7,8 or 9b except fire isolated exits |
Beaulieu | Trophy | 26oz/yd^2 SDN | Steplight | 2.3 | 218 | OK for buildings not fitted with sprinkler system. Class 2,3,5,6,7,8 or 9b |
Beaulieu | Trophy | 26oz/yd^2 SDN | Step 160 | 1.4 | 217 | OK for buildings fitted with sprinkler system. Class 2,3,5,6,7,8 or 9b except fire isolated exits |
Beaulieu | Trophy | 26oz/yd^2 SDN | Stepezy | 1.5 | 165 | OK for buildings fitted with sprinkler system. Class 2,3,5,6,7,8 or 9b except fire isolated exits |
Beaulieu | Trophy | 26oz/yd^2 SDN | Stepeco | 2.2 | 227 | OK for buildings not fitted with sprinkler system. Class 2,3,5,6,7,8 or 9b |
Beaulieu | Tuscan Sun | 30oz/yd^2 SDN | Stepsmart | 2.3 | 326 | OK for buildings not fitted with sprinkler system. Class 2,3,5,6,7,8 or 9b |
EC GROUP | 18 oz SDN | 18oz/yd^2 SDN | Stepezy | 1.6 | 157 | OK for buildings fitted with sprinkler system. Class 2,3,5,6,7,8 or 9b except fire isolated exits |
EC GROUP | Andes Peak | 35oz/yd^2 SDN | Stepezy | 2.2 | 201 | OK for buildings not fitted with sprinkler system. Class 2,3,5,6,7,8 or 9b |
EC GROUP | Avenue | 25 oz SDN | Stepezy | 2.3 | 174 | OK for buildings not fitted with sprinkler system. Class 2,3,5,6,7,8 or 9b |
EC GROUP | ESTATE | 25 oz SDN | Stepsmart | 1.2 | 321 | OK for buildings fitted with sprinkler system. Class 2,3,5,6,7,8 or 9b except fire isolated exits |
EC GROUP | Estate FR | 25 oz/yd^2 SDN | Steplight | 2.9 | 174 | OK for buildings not fitted with sprinkler system. Class 2,3,5,6,7,8 or 9b |
EC GROUP | Great Sandy | 34 oz/yd^2 WOOL | Stepezy | 3.6 | 151 | OK for buildings not fitted with sprinkler system. Class 2,3,5,6,7,8 or 9b |
EC GROUP | Laneway FR | 25 oz/yd^2 SDN | Steplight | 2.2 | 128 | OK for buildings not fitted with sprinkler system. Class 2,3,5,6,7,8 or 9b |
EC GROUP | Laneway FR | 26 oz/yd^2 SDN | Stepezy | 2.2 | 196 | OK for buildings not fitted with sprinkler system. Class 2,3,5,6,7,8 or 9b |
EC GROUP | Langhorne Hut | 30oz/yd^2 SDN | Stepezy | 1.9 | 196 | OK for buildings fitted with sprinkler system. Class 2,3,5,6,7,8 or 9b except fire isolated exits |
EC GROUP | Large Loop Pile | 30 oz/yd^2 SDN | Stepezy | 2.2 | 181 | OK for buildings not fitted with sprinkler system. Class 2,3,5,6,7,8 or 9b |
EC GROUP | Residence | 36 oz/yd^2, 100% SDN | Stepeco | 7.0 | 125 | Great in all areas. |
EC GROUP | Residence | 36 oz/yd^2, 100% wool | Steplight | 5.5 | 45 | Great in all areas. |
EC GROUP | Sensations FR | 28 oz/yd^2, 100% SDN | STEP 160 | 2.2 | 461 | OK for buildings not fitted with sprinkler system. Class 2,3,5,6,7,8 or 9b |
EC GROUP | Sensations FR | 29 oz/yd^2, 100% SDN | Steplight | 3.0 | 306 | OK for buildings not fitted with sprinkler system. Class 2,3,5,6,7,8 or 9b |
Feltex | 745GSM SDN LOOP (aka Wortstate) | 22 oz/yd^2 | Stepezy | 1.2 | 208 | OK for buildings fitted with sprinkler system. Class 2,3,5,6,7,8 or 9b except fire isolated exits |
Feltex | Amur | 26 oz/yd^2 (50/50 wool/Syn) | Steplight | 2.2 | 264 | OK for buildings not fitted with sprinkler system. Class 2,3,5,6,7,8 or 9b |
Feltex | Chantilly | 26oz 6mm pile (50/50) | Stepezy | 2.2 | 245 | OK for buildings not fitted with sprinkler system. Class 2,3,5,6,7,8 or 9b |
Feltex | Chantilly | 26oz 6mm pile (50/50) | Stepsmart | 2.2 | 260 | OK for buildings not fitted with sprinkler system. Class 2,3,5,6,7,8 or 9b |
Feltex | Mikado FR | 745gsm 8mm pile SDN | Stepezy | 3.3 | 122 | OK for buildings not fitted with sprinkler system. Class 2,3,5,6,7,8 or 9b |
Feltex | Mikado FR | 745gsm 8mm pile SDN | Stepsmart | 2.7 | 229 | OK for buildings not fitted with sprinkler system. Class 2,3,5,6,7,8 or 9b |
Feltex | Moderne FR | 28 oz/yd^2 SDN | Steplight Red | 2.2 | 285 | OK for buildings not fitted with sprinkler system. Class 2,3,5,6,7,8 or 9b |
Feltex | Mystic Charm | 32 oz/yd^2, 100% SDN | Stepsmart | 2.6 | 251 | OK for buildings not fitted with sprinkler system. Class 2,3,5,6,7,8 or 9b |
Feltex | Mystic Charm | 32 oz/yd^2, 100% SDN | Stepezy | 2.2 | 318 | OK for buildings not fitted with sprinkler system. Class 2,3,5,6,7,8 or 9b |
Feltex | Reactivate FR | 750 gsm 22 oz/yd^2 SDN | Stepezy | 2.7 | 233 | OK for buildings not fitted with sprinkler system. Class 2,3,5,6,7,8 or 9b |
Feltex | Radiance | 32 oz/yd^2, 100% SDN | Stepezy | 2.2 | 318 | OK for buildings not fitted with sprinkler system. Class 2,3,5,6,7,8 or 9b |
Feltex | Radiance | 32 oz/yd^2, 100% SDN | Stepsmart | 2.6 | 251 | OK for buildings not fitted with sprinkler system. Class 2,3,5,6,7,8 or 9b |
Feltex | Windsor Bay FR | 915gsm, 7mm pile SDN | Stepezy | 3.7 | 192 | OK for buildings not fitted with sprinkler system. Class 2,3,5,6,7,8 or 9b |
Feltex | Windsor Bay FR | 915gsm, 7mm pile SDN | Stepsmart | 3.1 | 211 | OK for buildings not fitted with sprinkler system. Class 2,3,5,6,7,8 or 9b |
Godfrey Hirst | 745GSM SDN LOOP (aka Wortstate) | 22 oz/yd^2 | Stepezy | 1.2 | 208 | OK for buildings fitted with sprinkler system. Class 2,3,5,6,7,8 or 9b except fire isolated exits |
Godfrey Hirst | Amur | 26 oz/yd^2, 50/50 W/Syn | Stepezy | 2.7 | 170 | OK for buildings not fitted with sprinkler system. Class 2,3,5,6,7,8 or 9b |
Godfrey Hirst | Ambition FR | 815gsm SDN 7mm | Stepezy | 4.4 | 224 | OK for buildings not fitted with sprinkler system. Class 2,3,5,6,7,8 or 9b |
Godfrey Hirst | Ambition FR | 815gsm SDN 7mm | Stepsmart | 4.6 | 274 | Great in all areas. |
Godfrey Hirst | Arabian Sands | 750gsm 50/50 W/SYN. | Stepsmart | 2.8 | 227 | OK for buildings not fitted with sprinkler system. Class 2,3,5,6,7,8 or 9b |
Godfrey Hirst | Arabian Sands | 750gsm 50/50 W/SYN. | Stepezy | 2.5 | 238 | OK for buildings not fitted with sprinkler system. Class 2,3,5,6,7,8 or 9b |
Godfrey Hirst | Arabian Sands | 750gsm 50/50 W/SYN. | Steplight | 2.7 | 216 | OK for buildings not fitted with sprinkler system. Class 2,3,5,6,7,8 or 9b |
Godfrey Hirst | Bayside Twist FR | 1090gsm SDN | Stepsmart | 3.2 | 268 | OK for buildings not fitted with sprinkler system. Class 2,3,5,6,7,8 or 9b |
Godfrey Hirst | Bayside Twist FR | 34 oz/yd^2 SDN 8.5mm | Stepezy | 3.5 | 197 | OK for buildings not fitted with sprinkler system. Class 2,3,5,6,7,8 or 9b |
Godfrey Hirst | Casa Twist | 26 oz/yd^2, 50/50 W/SDN | PROJECT 10 | 2.2 | 259 | OK for buildings not fitted with sprinkler system. Class 2,3,5,6,7,8 or 9b |
Godfrey Hirst | Casa Twist | 26 oz/yd^2, 50/50 W/SDN | Stepsmart | 2.2 | 260 | OK for buildings not fitted with sprinkler system. Class 2,3,5,6,7,8 or 9b |
Godfrey Hirst | Casa Twist | 26 oz/yd^2, 50/50 W/SDN | Stepezy | 2.2 | 245 | OK for buildings not fitted with sprinkler system. Class 2,3,5,6,7,8 or 9b |
Godfrey Hirst | Casse Velour | 36 oz, 50/50 W/SDN | Stepezy | 2.5 | 289 | OK for buildings not fitted with sprinkler system. Class 2,3,5,6,7,8 or 9b |
Godfrey Hirst | Casse Velour | 26 oz, 50/50 W/SDN | Steplight | 2.2 | 264 | OK for buildings not fitted with sprinkler system. Class 2,3,5,6,7,8 or 9b |
Godfrey Hirst | Classic City FR | 100% PET Fibre | Stepezy | 2.4 | 210 | OK for buildings not fitted with sprinkler system. Class 2,3,5,6,7,8 or 9b |
Godfrey Hirst | Newport | 28 oz/yd^2 | Stepezy | 5.1 | 257 | Great in all areas. |
Godfrey Hirst | Newport | 28 oz/yd^2 | Stepsmart | 3.7 | 346 | OK for buildings not fitted with sprinkler system. Class 2,3,5,6,7,8 or 9b |
Godfrey Hirst | Oregon | 22 oz/yd^2 | Stepezy | 1.2 | 326 | OK for buildings fitted with sprinkler system. Class 2,3,5,6,7,8 or 9b except fire isolated exits |
Godfrey Hirst | Oregon | 23 oz/yd^2 | Stepsmart | 1.4 | 254 | OK for buildings fitted with sprinkler system. Class 2,3,5,6,7,8 or 9b except fire isolated exits |
Godfrey Hirst | Oregon FR | 22oz/yd^2 SDN, 745 SGM | Steplight | 2.5 | 210 | OK for buildings not fitted with sprinkler system. Class 2,3,5,6,7,8 or 9b |
Godfrey Hirst | Seattle | 22 oz/yd^2 | Stepezy | 1.2 | 371 | OK for buildings fitted with sprinkler system. Class 2,3,5,6,7,8 or 9b except fire isolated exits |
Godfrey Hirst | Seattle | 22 oz/yd^2 | Stepsmart | 1.2 | 493 | OK for buildings fitted with sprinkler system. Class 2,3,5,6,7,8 or 9b except fire isolated exits |
Godfrey Hirst | Spinifex | 28 oz/yd^2, 100% Wool | Stepezy | 4.5 | 114 | OK for buildings not fitted with sprinkler system. Class 2,3,5,6,7,8 or 9b |
Godfrey Hirst | Supreme Touch | 45 oz/yd^2 | Stepeco | 3.8 | 167 | OK for buildings not fitted with sprinkler system. Class 2,3,5,6,7,8 or 9b |
Godfrey Hirst | Surrey | 30% Wool / 70% Poly Prop | Steplight | 2.3 | 214 | OK for buildings not fitted with sprinkler system. Class 2,3,5,6,7,8 or 9b |
Godfrey Hirst | Timeless | 35 oz/yd^2 100% NYLON | Stepezy | 4.0 | 152 | OK for buildings not fitted with sprinkler system. Class 2,3,5,6,7,8 or 9b |
Godfrey Hirst | Timeless | 35 oz/yd^2 100% NYLON | Stepsmart | 4.1 | 220 | OK for buildings not fitted with sprinkler system. Class 2,3,5,6,7,8 or 9b |
Godfrey Hirst | Tucson | 17 oz/yd^2 100% NYLON | Stepsmart | 1.3 | 371 | OK for buildings fitted with sprinkler system. Class 2,3,5,6,7,8 or 9b except fire isolated exits |
Godfrey Hirst | Tucson FR | 18 oz/yd^2, 610 GSM, 100% NYLON | Steplight | 2.2 | 350 | OK for buildings not fitted with sprinkler system. Class 2,3,5,6,7,8 or 9b |
Godfrey Hirst | Waterloo | 28 oz/yd^2, 51% W/49%Syn | Stepezy | 3.1 | 225 | OK for buildings not fitted with sprinkler system. Class 2,3,5,6,7,8 or 9b |
Godfrey Hirst / Feltex | 23 oz 30% Wool / 70% POLY (Surrey) | 30% Wool / 70% Poly Prop | Steplight | 2.3 | 214 | OK for buildings not fitted with sprinkler system. Class 2,3,5,6,7,8 or 9b |
Godfrey Hirst / Feltex | 26 oz 50/50 (YATALA) | 26 oz, 880 gsm 50% w / 50% sythetic | Stepeco | 2.2 | 268 | OK for buildings not fitted with sprinkler system. Class 2,3,5,6,7,8 or 9b |
Himalaya Carpets | Beijing 280 | 950 GSM, 100% GSM | Stepezy | 1.4 | 202 | OK for buildings fitted with sprinkler system. Class 2,3,5,6,7,8 or 9b except fire isolated exits |
Himalaya Carpets | Crosby / Katmandu | 950gsm, 50% w / 50% PET Fibre | Stepezy | 3.0 | 233 | OK for buildings not fitted with sprinkler system. Class 2,3,5,6,7,8 or 9b |
Himalaya Carpets | Meadow / Korala | 950gsm, 80% w / 20 % Nylon | Stepezy | 5.9 | 154 | Great in all areas. |
Himalaya Carpets | Bastia / Makalu | 750gsm, 100% wool | Stepezy | 5.9 | 99 | Great in all areas. |
Himalaya Carpets | Arniko | 950gsm, 50% w / 50% PET | Stepezy | 2.8 | 212 | OK for buildings not fitted with sprinkler system. Class 2,3,5,6,7,8 or 9b |
Himalaya Carpets | Chester / Mera | 1020gsm, 50% w / 50% PET | Stepezy | 3.4 | 215 | OK for buildings not fitted with sprinkler system. Class 2,3,5,6,7,8 or 9b |
Himalaya Carpets | Panama / Indus | 900gsm, 100% wool | Stepezy | 5.5 | 95 | Great in all areas. |
Himalaya Carpets | Lino | 2100 GSM, 100% SDN | Stepezy | 2.5 | 355 | OK for buildings not fitted with sprinkler system. Class 2,3,5,6,7,8 or 9b |
Himalaya Carpets | Hotham / Tyne 400 | 1360 GSM, 80% Wool / 20% PET Fibre | Stepezy | 4.6 | 71 | Great in all areas. |
Himalaya Carpets | Waverley | 1600 GSM, 100% Wool | Stepezy | 7.4 | 213 | Great in all areas. |
Himalaya Carpets | Kembla / Victoria | 1320 GSM, 50% Wool / 50% PET Fibre | Stepezy | 2.6 | 290 | OK for buildings not fitted with sprinkler system. Class 2,3,5,6,7,8 or 9b |
Himalaya Carpets | Proto | 1000 GSm, 30% Wool / 70% PET Fibre | Stepezy | 2.5 | 280 | OK for buildings not fitted with sprinkler system. Class 2,3,5,6,7,8 or 9b |
Northstate | 26 oz Series FR | 26 oz/yd^2 SDN | Stepsmart | 2.9 | 370 | OK for buildings not fitted with sprinkler system. Class 2,3,5,6,7,8 or 9b |
Northstate | 28 oz Series FR (aka Yorkton) | 28 oz/yd^2 SDN | Stepsmart | 2.9 | 194 | OK for buildings not fitted with sprinkler system. Class 2,3,5,6,7,8 or 9b |
Northstate | Brown Multi Loop (QUADRANCE) | 22 oz/yd^2, 100% PET Fibre | StepEzy | 2.8 | 201 | OK for buildings not fitted with sprinkler system. Class 2,3,5,6,7,8 or 9b |
Northstate | Hautier | 20oz/yd^2 100% PET Fibre | StepEzy | 1.4 | 156 | OK for buildings fitted with sprinkler system. Class 2,3,5,6,7,8 or 9b except fire isolated exits |
Northstate | Pet 28oz Cut | 28 oz/yd^2 100% PET Fibre | Stepezy | 1.5 | 149 | OK for buildings fitted with sprinkler system. Class 2,3,5,6,7,8 or 9b except fire isolated exits |
Northstate | Radium FR | 22 oz, 100%SDN | Stepezy | 1.2 | 229 | OK for buildings fitted with sprinkler system. Class 2,3,5,6,7,8 or 9b except fire isolated exits |
Northstate | Salina | 27oz/yd^2 100% PET Fibre | StepEzy | 1.2 | 323 | OK for buildings fitted with sprinkler system. Class 2,3,5,6,7,8 or 9b except fire isolated exits |
Quest Carpets | Pacific (Action Back Secondary Backing) | 32 oz/yd^2, 100% SDN | StepEzy | 1.2 | 186 | OK for buildings fitted with sprinkler system. Class 2,3,5,6,7,8 or 9b except fire isolated exits |
Quest Carpets | Pioneer FR | 24 oz/yd^2 SDN | Stepezy | 3.1 | 255 | OK for buildings not fitted with sprinkler system. Class 2,3,5,6,7,8 or 9b |
Quest Carpets | Pioneer FR | 24 oz/yd^2 SDN | StepLight | 4.0 | 249 | OK for buildings not fitted with sprinkler system. Class 2,3,5,6,7,8 or 9b |
Quest Carpets | Pluto | 60 oz/yd^2 | Steplight | 3.2 | 333 | OK for buildings not fitted with sprinkler system. Class 2,3,5,6,7,8 or 9b |
Quest Carpets | Rochford | 36 oz/yd^2, 100% SDN | Steplight | 1.2 | 334 | OK for buildings fitted with sprinkler system. Class 2,3,5,6,7,8 or 9b except fire isolated exits |
RC+D Carpets | Colorado | 850 GSM, 100% Wool | Steplight | 4.0 | 134 | OK for buildings not fitted with sprinkler system. Class 2,3,5,6,7,8 or 9b |
Tuftmaster Carpets | Angelia | 30oz/yd^2 SDN | Steplight | 2.2 | 280 | OK for buildings not fitted with sprinkler system. Class 2,3,5,6,7,8 or 9b |
Tuftmaster Carpets | Angelia | 30oz/yd^2 SDN | Steplux | 2.2 | 333 | OK for buildings not fitted with sprinkler system. Class 2,3,5,6,7,8 or 9b |
Tuftmaster Carpets | Contexture 111 | 813 GSM, 100% BCF NYLON | Stepsmart | 1.8 | 301 | OK for buildings fitted with sprinkler system. Class 2,3,5,6,7,8 or 9b except fire isolated exits |
Tuftmaster Carpets | Spring Ridge | 18 oz/yd^2 100% NYLON | Stepezy | 4.0 | 223 | OK for buildings not fitted with sprinkler system. Class 2,3,5,6,7,8 or 9b |
Tuftmaster Carpets | Soft Appeal | 2033 GSM, 100% BCF NYLON | Steplux | 3.6 | 371 | OK for buildings not fitted with sprinkler system. Class 2,3,5,6,7,8 or 9b |
Tuftmaster Carpets | Precinct | 20 oz/yd^2, 100% SDN | Steplux | 2.2 | 295 | OK for buildings not fitted with sprinkler system. Class 2,3,5,6,7,8 or 9b |
Tuftmaster Carpets | Contexture IV | 814GSM, 100% BCF Nylon | Stepsmart | 3.5 | 246 | OK for buildings not fitted with sprinkler system. Class 2,3,5,6,7,8 or 9b |
Tuftmaster Carpets | Review | 18 oz/yd^2, 100 SDN | Stepsupreme | 3.2 | 308 | OK for buildings not fitted with sprinkler system. Class 2,3,5,6,7,8 or 9b |
Tuftmaster Carpets | Hermes Twist | 847 GSM 100% BCF NYLON | Stepezy | 1.6 | 312 | OK for buildings fitted with sprinkler system. Class 2,3,5,6,7,8 or 9b except fire isolated exits |
Tuftmaster Carpets | 18oz SDN FRNC Loop (aka Spring Ridge FR) | 18 oz/yd^2 100% NYLON | Stepezy | 2.2 | 210 | OK for buildings not fitted with sprinkler system. Class 2,3,5,6,7,8 or 9b |
Tuftmaster Carpets | Rustic Style | 22 oz/yd^2 100% SDN | Steplux | 4.0 | 257 | OK for buildings not fitted with sprinkler system. Class 2,3,5,6,7,8 or 9b |
Tuftmaster Carpets | Contexture 111 FRNC | 24 oz/yd^2 100% SDN | Steplux | 2.8 | 196 | OK for buildings not fitted with sprinkler system. Class 2,3,5,6,7,8 or 9b |
Victorian Carpets | Central Boulevard | 1220 gsm 80% wool 20% Poly | Stepezy | 3.0 | 235 | OK for buildings not fitted with sprinkler system. Class 2,3,5,6,7,8 or 9b |
Victorian Carpets | City Living Plush | 26 oz/yd^2 50% wool 50% Syn | Steplight | 1.6 | 277 | OK for buildings fitted with sprinkler system. Class 2,3,5,6,7,8 or 9b except fire isolated exits |
Victorian Carpets | Penthouse décor | 950 gsm 80% Wool 20% Poly | Stepezy | 2.6 | 230 | OK for buildings not fitted with sprinkler system. Class 2,3,5,6,7,8 or 9b |
Victorian Carpets | Penthouse Squares | 26 oz/yd^2 50/50 W/POLY | Steplight | 1.2 | 317 | OK for buildings fitted with sprinkler system. Class 2,3,5,6,7,8 or 9b except fire isolated exits |
Victorian Carpets | Penthouse Velour | 26 oz/yd^2 50/50 W/POLY | Stepezy | 2.6 | 232 | OK for buildings not fitted with sprinkler system. Class 2,3,5,6,7,8 or 9b |
Victorian Carpets | Tudor twist | 1085 gsm 80% wool 20% Poly | Stepezy | 3.3 | 272 | OK for buildings not fitted with sprinkler system. Class 2,3,5,6,7,8 or 9b |
Victorian Carpets | Tudor Twist Supreme | 40 oz/yd^2 80% Wool 20% Poly | Stepezy | 2.7 | 236 | OK for buildings not fitted with sprinkler system. Class 2,3,5,6,7,8 or 9b |
Godfrey Hirst | Tiburon | 28oz/yd^2 Wool | Stepezy | 6.3 | 102 | Great in all areas. |
Godfrey Hirst | Supreme Touch | 45oz/yd^2 SDN | Stepezy | 2.9 | 256 | OK for buildings not fitted with sprinkler system. Class 2,3,5,6,7,8 or 9b. With sprinklers All classes OK except fire isolated exits. |
Godfrey Hirst | Refined Appeal | 1430GSM SDN | Stepezy | 4.0 | 237 | OK for buildings not fitted with sprinkler system. Class 2,3,5,6,7,8 or 9b. With sprinklers All classes OK except fire isolated exits. |
Godfrey Hirst | Refined Appeal | 1430GSM SDN | Stepsmart | 2.5 | 328 | OK for buildings not fitted with sprinkler system. Class 2,3,5,6,7,8 or 9b. With sprinklers All classes OK except fire isolated exits. |